Evaluation of locoregional invasiveness of small-sized non-small cell lung cancers by enhanced dual-energy computed tomography

Abstract

Background

To investigate the correlation between iodine-related attenuation of dual-energy computed tomography (DE-CT) and the histopathological invasiveness of surgically resected primary non-small cell lung cancers (NSCLCs) ≤ 3 cm in diameter.

Methods

We selected 63 consecutive NSCLC lesions from 60 patients (32 males, 28 females; age range, 39–85 years; mean age, 68 years). After injection of iodinated contrast media, arterial phases were scanned using 140-kVp and 80-kVp tube voltages. Three-dimensional iodine-related attenuation (3D-IRA) of primary tumors at the arterial phase was computed using “lung nodule” application software. The corrected 3D-IRA normalized to the patient’s body weight and contrast medium concentration was then calculated. Single-factor analysis of variance (ANOVA) was used for comparison among tumor differentiation grade groups. Univariate and multivariate logistic regression analysis was used for the correlation between locoregional invasive tumor and clinical factors.

Results

Resected tumors were histopathologically classified into well-differentiated (G1; n = 24), moderately-differentiated (G2; n = 28), and poorly-differentiated (G3; n = 11) groups by degree of tumor differentiation. The mean ± standard deviation of the 3D-IRA was 56.1 ± 22.6 HU in G1 tumours, 48.5 ± 23.9 HU in G2 tumours, and 28.4 ± 15.8 HU in G3 tumours; significant differences were observed between groups by ANOVA. (p = 0.005). Univariate logistic analysis showed that the 3D-IRA and corrected 3D-IRAs were significantly correlated with locoregional invasive tumors (p = 0.002 and p < 0.001, respectively). Multivariate logistic analysis revealed that only the corrected 3D-IRA was significantly correlated with tumor invasiveness (p = 0.003), while gender, clinical size, and solid/subsolid type were not (p = 0.950, p = 0.057 and p = 0.456, respectively).

Conclusions

The 3D-IRA of small-sized NSCLCs was significantly associated with and invasiveness. Low 3D-IRA tumors tended to have greater invasiveness than high 3D-IRA tumors.

Background

The prognosis and malignancy of primary lung cancer are affected by histopathological findings [1, 2]. For resectable non-small cell lung cancers (NSCLCs), preoperative diagnostic imaging is essential for determining the best therapeutic strategy, including the type of surgical procedure [35]. In the tumor, nodes, and metastasis (TNM) classification, T descriptors reflect tumor size and locoregional invasiveness. Tumor size can be measured definitively on thin-section computed tomography (CT) with a slice thickness of ≤ 1 mm. However, it is difficult to evaluate microscopic tumor invasiveness, such as pleural involvement, lymphatic permeation, and vascular invasion, even on thin-section CT.

Contrast-enhanced CT has been used in functional imaging to evaluate intratumoral necrosis, vascularity, and fibrosis, which are associated with invasiveness and prognosis [68]. A dual-energy CT (DE-CT) technique using two types of tube voltage has enabled quantification of the iodine-related attenuation of iodinated contrast material in the tumor after intravenous injection, without the need for an additional non-contrast CT scan [912]. It leads to radiation exposure reduction of a patient in a CT examination. Recently, Baxa et al. reported that iodine uptake at the arterial phase of dual phase contrast DE-CT is a feasible method in assessment of anti-EGFR therapy response for NSCLC [13]. Aoki et al. reported that iodine uptake at the arterial phase of contrast DE-CT is useful quantitative assessment for predicting lung cancer recurrence after stereotactic body radiotherapy [14]. That is, tumors with lower iodine uptake for pretreatment evaluation showed a worse prognosis after radiotherapy. These research findings indicate that iodine uptake at the arterial phase on contrast CT may be associated with some sort of tumor histopathology such as angiogenesis and hypoxic cell. Our recent study demonstrated that the three-dimensional iodine-related attenuation (3D-IRA; also known as “iodine volume”) of primary lung cancers measured by contrast-enhanced DE-CT was significantly associated with their differentiation grade [15]. Tumor grade correlates directly with microscopic tumor invasiveness [1618]. Therefore, we speculated that the 3D-IRA might correlate indirectly with the microscopic invasiveness of small-sized NSCLCs. If that is true, a dual-energy technique would enable preoperative prediction of tumor invasiveness.

In this study, we reviewed preoperative data from contrast CT with dual-energy scanning as well as postoperative histopathological findings of NSCLCs ≤ 3 cm that were surgically resected, and validated the hypothesis that the 3D-IRA of the primary lesion could be a predictive factor for locoregional invasiveness.

Methods

Patient selection

We reviewed the medical records, post-operative pathological records, and preoperative DE-CT images of patients who underwent surgical lung resection for primary lung cancer at our hospital between April 2014 and March 2015. We limited these patients to those with NSCLCs of ≤ 3 cm in diameter that had been definitively diagnosed by pathological examination after surgical resection. Non-solid types of lung cancer that were invisible on mediastinal window settings for thoracic CT were excluded. Patients who received preoperative chemoradiotherapy were also excluded. We recorded patient characteristics (gender, age, and body weight) from medical records, and tumor characteristics (pathological tumor size, histological type, differentiation grade, lymphatic permeation, vascular invasion, and pleural involvement) from pathological records. Herein, the differentiation grade was classified into the following groups: G1, well-differentiated; G2, moderately-differentiated; and G3, poorly-differentiated. We defined locoregional invasive tumors as tumors that had at least one invasive pathologic finding (lymphatic permeation, vascular invasion, or pleural involvement) and non-invasive tumors as tumors that had no invasive pathologic findings [19, 20].

CT scan protocol

All CT scans were performed with a dual-source CT scanner (SOMATOM Definition Flash; Siemens Healthcare, Tokyo, Japan) in the craniocaudal direction with inspiratory apnea. For vessel enhancement, 96 mL of non-ionic contrast medium (Proscope 300, 300 mgI/mL iopromide, Alfresa Pharma, Osaka, Japan; Optiray 320, 320 mgI/mL ioversol, Tyco Healthcare, Tokyo, Japan; or iopamiron 370, 370 mgI/mL iopamidol, Bayer Healthcare, Tokyo, Japan) were used with flow rates of 4.0 mL/sec. Iopromide was used for patients with body weights < 40 kg, ioversol was used for patients with body weights 40–59 kg, and Iopamidol was used for patients with body weights ≥ 60 kg. Injections were immediately followed by a saline chaser bolus of 20 mL at the same flow rate using a dual-barrel power injector (Dual Shot GX7; Nemoto Kyorindo, Tokyo, Japan).

In our institution, the dual-phase dynamic CTs were performed routinely to preoperative evaluation of lung cancer. After pre-contrast CT scan, the early phase of thoracic CT has been scanned for preoperative evaluation of pulmonary vessels by 3D-pulmonary angiography. The scan delay was evaluated by an automatic bolus tracking system with a circular ROI localized on the thoracic aorta. Scanning started automatically as the attenuation of the ROI increased 70 HU from baseline (about 20–25 sec. after start of injection). A dual-energy scan system (tube A at a peak voltage of 140 kVp and tube B at a peak voltage of 80 kVp) was used for both scans with collimation, 64 × 0.6 mm; gantry rotation speed, 285 msec. Additionally, the delayed phase of thoraco-abdominal CT has been scanned to evaluate lymph node metastasis and abdominal distant metastasis about 2 min later of contrast medium injection. Data were reconstructed with a slice thickness of 1.0-mm at 1.0-mm increments using iterative reconstruction techniques (SAFIRE, Siemens Healthcare, Tokyo, Japan).

Analysis of dual-energy CT images

The 3D-IRA of the primary lesion was measured using the syngo “lung nodules” application accessory software [15, 21]. The DE-CT technique can create iodine-enhanced images from DE-CT raw data sets of 140kVp and 80kVp, and measure absolute quantification of iodine within the tumors. This application can automatically segment a pulmonary nodule and calculate the mean iodine related attenuation of pulmonary nodules with a three-material decomposition algorithm. A chest radiologist who had 21 years of experience reading thoracic CT scans segmented the primary tumor, measured the maximum diameter as clinical tumor size, and recorded the 3D-IRA.

Additionally, corrected 3D-IRA values to reduce the effect of body weight and iodine concentration of contrast medium, were calculated as follows:

$$ Corrected\kern0.5em 3D-IRA=\frac{raw\kern0.5em data\kern0.5em of 3D-IRA}{Concentration\kern0.5em of\kern0.5em contrast\kern0.5em medium\kern0.5em \left[\mathrm{m}\mathrm{g}\mathrm{I}\right]/ Body\kern0.5em weight\left[\mathrm{kg}\right]} $$

Representative cases of CT and iodine-enhanced images are shown in Figs. 1 and 2.

Fig. 1
figure 1

A 66-year-old female patient. A well-differentiated (G1) adenocarcinoma is observed in the left lower lobe. Lymphatic permeation, vascular invasion, and pleural involvement were all negative. a Lung window setting. b Mediastinal window setting. c Iodine-enhanced image of contrast-enhanced CT. The 3D-IRA is 47 HU, and the corrected 3D-IRA is 8.13

Fig. 2
figure 2

A 74-year-old female patient. A poorly-differentiated (G3) adenocarcinoma is observed in the left lingula. Vascular invasion, and pleural involvement were positive. a Lung window setting. b Mediastinal window setting. c Iodine-enhanced image of contrast-enhanced CT. The 3D-IRA is 16 HU, and the corrected 3D-IRA is 2.85

Statistical analysis

First, among the three differentiation grade groups (G1 to G3), possible differences in patient characteristics were compared. Gender, ratio of part-solid nodules to solid nodules, locoregional invasive tumor, and lymph node metastases were compared by chi-square test. The age, body weight, clinical and pathological tumor size, 3D-IRA, and corrected 3D-IRA were compared by single-factor analysis of variance (ANOVA). Second, correlations between tumor characteristics and locoregional invasive tumors were individually evaluated using univariate logistic regression analysis. Third, areas under the curve of receiver operating characteristic (ROC) analysis for diagnosis of locoregional invasive tumor were compared between the 3D-IRAs and the corrected 3D-IRAs. Then, Youden’s index was used to determine a cut-off level that would indicate a locoregional invasive tumor. Last, multivariate logistic regression analysis was used for the correlation between locoregional invasive tumor and clinical factors for which the p-value was < 0.2 by univariate logistic analysis.

Analyses were performed using commercial statistical software: Excel 2010 (Microsoft Corp., Redmond, WA) and SPSS version 23 (IBM Corp., Amonk, NY). A p-value < 0.05 was considered statistically significant.

Results

A total of 73 resected pulmonary lesions were reviewed, and 10 lesions were excluded because they were non-solid type (Fig. 3). Finally, 63 consecutive primary lung cancer lesions from 60 patients were selected for analysis (32 males and 28 females; mean age, 67 years [range, 39–85 years]; mean body weight, 58.2 kg [range, 37–85 kg]). Of these lesions, 54 were adenocarcinomas, 8 were squamous cell carcinomas, and 1 was adenosquamous carcinoma.

Fig. 3
figure 3

Study cohort flow chart. A total of 73 surgically resected pulmonary lesions were scanned preoperatively with DE-CT. After exclusion criteria were applied, 63 primary NSCLCs were included in the present analysis

Table 1 compares patient and tumor characteristics among differentiation grade groups. The mean ± standard deviation (SD) of 3D-IRA at the arterial phase was 56.1 ± 22.6 HU in G1 tumors, 48.5 ± 23.9 HU in G2 tumours, and 28.4 ± 15.8 HU in G3 tumours. The 3D-IRA was significantly different among the three differentiation grades (p = 0.005). The corrected 3D-IRA was also significantly different among the three differentiation grades (p = 0.005). Higher-grade tumors had lower 3D-IRA values. The percentage of locoregional invasiveness and lymph node metastases was significantly higher in high-grade tumors (p = 0.044 and p = 0.012, respectively). The ratios of female and part-solid type tumors were significantly higher in low-grade tumors (p = 0.001, and p <0.001, respectively). For age, body weight, and tumor size (both clinical and pathological), no significant differences were observed among the three groups (p = 0.912, p = 0.677, p = 0.758, and p = 0.069, respectively).

Table 1 Comparison of patient and tumor characteristics among differentiation grade groups

Table 2 shows the association between clinical or pathological factors and locoregional invasive tumor using univariate logistic regression analysis. Among the clinical factors, the 3D-IRA and the corrected 3D-IRA were significantly correlated with locoregional invasive tumors (p = 0.002 and p < 0.001, respectively). The gender, clinical tumor size, and internal opacity type of the clinical factors that were indicated as p-value <0.2 were adopted for subsequent multivariate logistic analysis. Among the pathological factors, the size and differentiation grade were significantly correlated with locoregional invasive tumors (p = 0.006 and p = 0.017, respectively).

Table 2 Univariate logistic analysis of clinical and pathological factors for locoregional invasiveness

Figure 4 shows the ROC curves of the 3D-IRA and the corrected 3D-IRA for diagnosis of locoregional invasive tumors. The AUC of the 3D-IRA was 0.776 (95 % confidence interval, 0.658 - 0.894) and that of the corrected 3D-IRA was 0.781 (95 % confidence interval, 0.664–0.899). The AUC of the corrected 3D-IRA was higher than that of the 3D-IRA; however, the difference was not significant (p = 0.738). A suitable cutoff value for the corrected 3D-IRA was estimated to be 5.74. This value yielded 62.1 % sensitivity and 88.2 % specificity for determination of locoregional invasive tumors. From this result, the corrected 3D-IRA was used as a factor for multivariate logistic analysis.

Fig. 4
figure 4

ROC curves of the 3D-IRA and the corrected 3D-IRA for diagnosis of locoregional invasive tumor

Table 3 shows the correlation between locoregional invasiveness and four clinical factors, including gender, clinical tumor size, internal opacity, and corrected 3D-IRA by multivariate logistic regression analysis. Among these four factors, only the corrected 3D-IRA was significantly correlated with locoregional invasive tumors (p = 0.003). For gender, clinical tumor size, and solid vs. subsolid tumors, no significant differences were observed (p = 0.950, p = 0.057, and p = 0.456, respectively).

Table 3 Multivariate logistic analysis for locoregional invasive tumor

Discussion

This study was designed to assess the role of enhanced DE-CT for small-sized NSCLC resected surgically and confirmed histopathologically. We researched the following two points: 1) Is the 3D-IRA associated with the differentiation grade, even in NSCLCs ≤ 3 cm in diameter? 2) Are the 3D-IRAs correlated with their invasiveness? This study revealed that the 3D-IRA was significantly correlated with differentiation grade. High-grade NSCLCs tended to show low contrast enhancement. In addition, only the corrected 3D-IRA was significantly correlated with locoregional invasiveness among four independent variables (gender, size, internal characteristics on CT, and corrected 3D-IRA) according to multivariate logistic regression analysis. Consequently, the present results demonstrated that contrast-enhanced DE-CT could diagnose malignant potential as well as fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT).

The 3D-IRA and the corrected 3D-IRA of G3 NSCLCs were lower than those of G1 and G2 tumors. This result corresponds well with that of our previous study, which reported that G3 tumors showed significantly lower enhancement than G1 and G2 tumors [15]. This investigation suggested this occurred primarily due to intratumoral necrosis and fibrosis, which are closely correlated with invasiveness and prognosis of NSCLCs. In the present study, the frequency of locoregional invasive tumors in G3 tumors was higher than that in G1 and G2 tumors.

Therefore, we investigated the correlation between the 3D-IRA and degree of locoregional invasion in primary lesions. As we expected, according to univariate logistic regression analysis, the 3D-IRA, corrected 3D-IRA, pathological tumor size, and differentiation grade were significantly correlated with locoregional invasiveness. Furthermore, by multivariate logistic analysis, only the corrected 3D-IRA was significantly correlated with locoregional invasiveness among the clinical independent variables that were preoperatively obtainable. Thus, the 3D-IRA may be useful for selecting a therapeutic strategy, such as limited resection to preserve pulmonary function. Wedge resection or segmentectomy for small primary lung cancers are currently recommended for non-invasive tumors [22]. However, for small-sized lung tumors, it is sometimes difficult for transbronchial lung biopsy and CT-guided transcutaneous needle biopsy to determine the differentiation grade. An intraoperative diagnosis based on frozen sections and needle biopsies is also known to have limitations due to the potential risks of physical complications, false-negative results, and the implantation of cancer cells [2325].

According to our univariate logistic regression analysis, both the 3D-IRA and corrected 3D-IRA that is the values were corrected by body weight and concentration of contrast materials, were significantly correlated with tumor invasiveness. Thus, we investigated which value was better correlated with invasiveness by ROC analysis. As a result, the corrected values showed a higher AUC than the raw ones, although no significant difference was observed. Therefore, we used the corrected values for multivariate logistic regression analysis.

PET/CT is useful for estimating the malignancy and invasiveness of lung tumors. The maximum standardized uptake value (SUVmax) has been commonly used to evaluate the invasiveness and prognosis of NSCLC. We believe that the 3D-IRA measured by DE-CT has three advantages over SUVmax on PET/CT for evaluation of lung cancer. First, 3D-IRA can be measured not only in large-sized but also small-sized tumors, as revealed in the present study. The lesion size is significantly associated with FDG uptake [2628]. In particular, lesions ≤ 2 cm tended to have negative PET findings. Second, this was not influenced by respiratory variation because high-speed dual source CT can evaluate the whole lung in several seconds. Third, CT is less expensive than PET/CT. A previous study revealed that the SUVmax was negatively correlated with 3D-IRA [15]. Further investigation of the comparison with PET/CT is required.

This retrospective study has several limitations. First, we excluded non-solid type tumors from our study cohort, because it was difficult to measure 3D-IRA automatically using software. This represents a selection bias, as non-solid type lung adenocarcinoma is usually non-invasive [19, 29, 30]. Second, we could not evaluate differences between adenocarcinomas and squamous cell carcinomas because the number of squamous cell carcinoma cases was relatively small. Previous FDG-PET/CT studies demonstrate that SUVs of squamous cell carcinomas are higher than those of adenocarcinomas [20, 31, 32]. Third, since the number of patients with lymph node metastasis was relatively small, we could not evaluate the correlation with the 3D-IRA of small-sized NSCLCs. Finally, the radiation dose on contrast enhanced CT was not compared between DE-CT and conventional single energy CT. However, the recent study of Uhrig et al. demonstrated that abdominal DE-CT is feasible without increasing radiation dose or deteriorating image quality, even compared to single energy CT [33].

Conclusions

The 3D-IRA of small-sized NSCLCs measured by DE-CT was significantly associated with differentiation grade and invasiveness. Primary lung cancers with lower 3D-IRA tended to have a high grade and be more invasive.

Abbreviations

3D-IRA, three-dimensional iodine-related attenuation; ANOVA, analysis of variance; AUC, area under the curve; DE-CT, dual-energy computed tomography; FDG-PET/CT, fluorodeoxyglucose positron emission tomography/computed tomography; NSCLC, non-small cell lung cancer; ROC, receiver operating characteristic; ROI, region of interest

References

  1. Chung CK, Zaino R, Stryker JA, O’Neill Jr M, DeMuth Jr WE. Carcinoma of the lung: evaluation of histological grade and factors influencing prognosis. Ann Thorac Surg. 1982;33(6):599–604.

    Article  CAS  PubMed  Google Scholar 

  2. Kozu Y, Maniwa T, Takahashi S, Isaka M, Ohde Y, Nakajima T. Risk factors for both recurrence and survival in patients with pathological stage I non-small-cell lung cancer. Eur J Cardiothorac Surg. 2013;44(1):e53–8.

    Article  PubMed  Google Scholar 

  3. Kishimoto M, Iwano S, Ito S, Kato K, Ito R, Naganawa S. Prognostic evaluations of small size lung cancers by 18 F-FDG PET/CT and thin-section CT. Lung Cancer. 2014;86(2):180–4.

    Article  PubMed  Google Scholar 

  4. Iwano S, Yokoi K, Taniguchi T, Kawaguchi K, Fukui T, Naganawa S. Planning of segmentectomy using three-dimensional computed tomography angiography with a virtual safety margin: Technique and initial experience. Lung Cancer. 2013;81(3):410–5.

    Article  PubMed  Google Scholar 

  5. Billé A, Pelosi E, Skanjeti A, Arena V, Errico L, Borasio P, et al. Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography. Eur J Cardiothorac Surg. 2009;36(3):440–5.

    Article  PubMed  Google Scholar 

  6. Iwano S, Koike W, Matsuo K, Okada T, Shimoyama Y, Naganawa S. Correlation between dual-phase dynamic multi-detector CT findings and fibrosis within lung adenocarcinoma tumors. Eur J Radiol. 2011;80(3):e470–5.

    Article  PubMed  Google Scholar 

  7. Spira D, Neumeister H, Spira SM, Hetzel J, Spengler W, von Weyhern CH, et al. Assessment of tumor vascularity in lung cancer using volume perfusion CT (VPCT) with histopathologic comparison: a further step toward an individualized tumor characterization. J Comput Assist Tomogr. 2013;37(1):15–21.

    Article  PubMed  Google Scholar 

  8. Wang Y, Wang J-a, Liang K-r, Liang M-z, X-g L. Correlations between tumor stroma characters and dynamic enhanced MDCT findings in nodular pulmonary adenocarcinoma. J Comput Assist Tomogr. 2014;38(1):82–8.

    Article  CAS  PubMed  Google Scholar 

  9. Zhang LJ, Yang GF, Wu SY, Xu J, Lu GM, Schoepf UJ. Dual-energy CT imaging of thoracic malignancies. Cancer Imaging. 2013;13:81–91.

    Article  PubMed  Google Scholar 

  10. Schmid-Bindert G, Henzler T, Chu TQ, Meyer M, Nance Jr JW, Schoepf UJ, et al. Functional imaging of lung cancer using dual energy CT: how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT? Eur Radiol. 2012;22(1):93–103.

    Article  CAS  PubMed  Google Scholar 

  11. Baxa J, Vondrakova A, Matouskova T, Ruzickova O, Schmidt B, Flohr T, et al. Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response. Eur Radiol. 2014;24(8):1981–8.

    Article  PubMed  Google Scholar 

  12. Sudarski S, Hagelstein C, Weis M, Schoenberg SO, Apfaltrer P. Dual-energy snap-shot perfusion CT in suspect pulmonary nodules and masses and for lung cancer staging. Euro J Radiol. 2015;84(12):2393–400.

    Article  Google Scholar 

  13. Baxa J, Matouskova T, Krakorova G, Schmidt B, Flohr T, Sedlmair M, Bejcek J, Ferda J. Dual-Phase Dual-Energy CT in Patients Treated with Erlotinib for Advanced Non-Small Cell Lung Cancer: Possible Benefits of Iodine Quantification in Response Assessment. Eur Radiol. 2015. doi:10.1007/s00330-015-4092-6.

  14. Aoki M, Hirose K, Sato M, Akimoto H, Kawaguchi H, Hatayama Y, Fujioka I, Tanaka M, Ono S, Takai Y. Prognostic impact of average iodine density assessed by dual-energy spectral imaging for predicting lung tumor recurrence after stereotactic body radiotherapy. J Radiat Res. 2016. doi:10.1093/jrr/rrv100.

  15. Iwano S, Ito R, Umakoshi H, Ito S, Naganawa S. Evaluation of lung cancer by enhanced dual-energy CT: association between three-dimensional iodine concentration and tumour differentiation. Br J Radiol. 2015;88(1055):20150224.

    Article  PubMed  Google Scholar 

  16. Al-Alao BS, Gately K, Nicholson S, McGovern E, Young VK, O’Byrne KJ. Prognostic impact of vascular and lymphovascular invasion in early lung cancer. Asian Cardiovasc Thorac Ann. 2014;22(1):55–64.

    Article  PubMed  Google Scholar 

  17. Pechet TT, Carr SR, Collins JE, Cohn HE, Farber JL. Arterial invasion predicts early mortality in stage I non-small cell lung cancer. Ann Thorac Surg. 2004;78:1748–53.

    Article  PubMed  Google Scholar 

  18. Poncelet AJ, Cornet J, Coulon C, Collard P, Noirhomme P, Weynand B. Intra-tumoral vascular or perineural invasion as prognostic factors for long-term survival in early stage non-small cell lung carcinoma. Eur J Cardiothorac Surg. 2008;33:799–804.

    Article  PubMed  Google Scholar 

  19. Iwano S, Kishimoto M, Ito S, Kato K, Ito R, Naganawa S. Prediction of pathologic prognostic factors in patients with lung adenocarcinomas: comparison of thin-section computed tomography and positron emission tomography/computed tomography. Cancer Imaging. 2014;14:3. doi:10.1186/1470-7330-14-3.

    PubMed  PubMed Central  Google Scholar 

  20. Ito R, Iwano S, Kishimoto M, Ito S, Kato K, Naganawa S. Correlation between FDG-PET/CT findings and solid type non-small cell cancer prognostic factors: are there differences between adenocarcinoma and squamous cell carcinoma? Ann Nucl Med. 2015;29(10):897–905.

    Article  CAS  PubMed  Google Scholar 

  21. Chae EJ, Song JW, Krauss B, Song KS, Lee CW, Lee HJ, Seo JB. Dual-energy computed tomography characterization of solitary pulmonary nodules. J Thorac Imaging. 2010;25(4):301–10. doi:10.1097/RTI.0b013e3181e16232.

    Article  PubMed  Google Scholar 

  22. Yoshida J, Ishii G, Hishida T, Aokage K, Tsuboi M, Ito H, et al. Limited resection trial for pulmonary ground-glass opacity nodules: case selection based on high-resolution computed tomography-interim results. Jpn J Clin Oncol. 2015;45(7):677–81.

    Article  PubMed  Google Scholar 

  23. Ozeki N, Iwano S, Taniguchi T, Kawaguchi K, Fukui T, Ishiguro F, et al. Therapeutic surgery without a definitive diagnosis can be an option in selected patients with suspected lung cancer. Interact Cardiovasc Thorac Surg. 2014;19(5):830–7.

    Article  PubMed  Google Scholar 

  24. Gould MK, Donington J, Lynch WR, Mazzone PJ, Midthun DE, Naidrich DP, et al. Evaluation of individuals with pulmonary nodules: when is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143(5 Suppl):e93S–120.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Wiener RS, Schwartz LM, Woloshin S, Welch HG. Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records. Ann Intern Med. 2011;155:137–44.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Iwano S, Ito S, Tsuchiya K, Kato K, Naganawa S. What causes false-negative PET findings for solid-type lung cancer? Lung Cancer. 2013;79(2):132–6.

    Article  PubMed  Google Scholar 

  27. Suzawa N, Ito M, Qiao S, Uchida K, Takao M, Yamada T, et al. Assessment of factors influencing FDG uptake in non-small cell lung cancer on PET/CT by investigating histological differences in expression of glucose transporters 1 and 3 and tumour size. Lung Cancer. 2011;72(2):191–8.

    Article  PubMed  Google Scholar 

  28. Nomori H, Watanabe K, Ohtsuka T, Naruke T, Suemasu K, Uno K. Evaluation of F-18 fluorodeoxyglucose (FDG) PET scanning for pulmonary nodules less than 3 cm in diameter, with special reference to the CT images. Lung Cancer. 2004;45(1):19–27.

    Article  PubMed  Google Scholar 

  29. Asamura H, Hishida T, Suzuki K, Koike T, Nakamura K, Kusumoto M, et al. Radiographically determined noninvasive adenocarcinoma of the lung: survival outcomes of Japan Clinical Oncology Group 0201. J Thorac Cardiovasc Surg. 2013;146(1):24–30.

    Article  PubMed  Google Scholar 

  30. Ohde Y, Nagai K, Yoshida J, Nishimura M, Takahashi K, Suzuki K, et al. The proportion of consolidation to ground-glass opacity on high resolution CT is a good predictor for distinguishing the population of non-invasive peripheral adenocarcinoma. Lung Cancer. 2003;42(3):303–10.

    Article  PubMed  Google Scholar 

  31. Muto J, Hida Y, Kaga K, Ohtaka K, Okamoto S, Tamaki N, et al. Use of maximum standardized uptake value on fluorodeoxyglucose positron-emission tomography in predicting lymph node involvement in patients with primary non-small cell lung cancer. Anticancer Res. 2014;34(2):805–10.

    PubMed  Google Scholar 

  32. Li M, Sun Y, Liu Y, Han A, Zhao S, Ma L, et al. Relationship between primary lesion FDG uptake and clinical stage at PET-CT for non-small cell lung cancer patients: An observation. Lung Cancer. 2010;68(3):394–7.

    Article  PubMed  Google Scholar 

  33. Uhrig M, Simons D, Kachelrieß M, Pisana F, Kuchenbecker S, Schlemmer HP. Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging. 2016;16(1):15. doi:10.1186/s40644-016-0073-5.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

None.

Funding

This work was supported by KAKENHI (15 K09919) from the Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT).

Availability of data and materials

All data analyzed during this study are included in this published article.

Authors’ contributions

HS participated in the data acquisition, performed the statistical analysis and drafted the manuscript. SI conceived of the study, and participated in its design and coordination and helped to draft the manuscript. HU helped the data acquisition and the statistical analysis. KK conceived of the study, and participated in the data acquisition. SN contributed to the data interpretation, and manuscript editing. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

This retrospective study was approved by our institutional review board (Ethics committee of Nagoya University Graduate School of Medicine) with a waiver of informed consent for retrospective data analysis of patients with surgically and histologically confirmed lung cancer who underwent DE-CT for a clinical indication at our institution (No. 2015–0100).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shingo Iwano.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shimamoto, H., Iwano, S., Umakoshi, H. et al. Evaluation of locoregional invasiveness of small-sized non-small cell lung cancers by enhanced dual-energy computed tomography. Cancer Imaging 16, 18 (2016). https://doi.org/10.1186/s40644-016-0077-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40644-016-0077-1

Keywords