Ultrasound with microbubbles

Conventional ultrasound has well known short comings in the detection and characterisation of focal liver lesions. A false negative rate of up to 30% has been quoted in the detection of liver metastases and its accuracy in the characterisation of focal liver lesions is poor compared to computed tomography (CT) and magnetic resonance (MR). Ultrasound microbubble contrast agents have redressed these limitations.

Ultrasound microbubbles have been available for over 20 years and are licensed for clinical use in most parts of the world. The characterization of focal liver lesions is the most important application of contrast-enhanced US (CEUS), with an accuracy rivalling that of CT and MR [18].

Microbubbles consist of a low solubility complex gas such as a perfluoro gas surrounded by a phospholipid shell. They are similar in size to red blood cells, in comparison to the molecular sizes of CT and MR contrast agents. They are pure intravascular agents. Following an intravenous injection they last in the circulation for about 5 minutes. By good fortune, microbubbles resonate in an ultrasound field at the frequencies used in everyday diagnostic sonography. During resonance they emit ‘fingerprint like’ harmonic signals (overtones) which can be selectively detected by the microbubble-specific software available on commercial ultrasound systems. Microbubbles are imaged using low acoustic power modes to reduce their destruction and thus allow real-time imaging. They are better tolerated than MR and CT agents with fewer and less severe adverse effects and are not nephrotoxic. The most widely used agent in Europe is Sonovue (Bracco).

The liver demonstrates three phases of enhancement after an i.v. bolus injection: the arterial, portal and late phases. The late phase occurs as the vascular phases subside, when the microbubbles are sequestered in the sinusoids of the liver.

Enhancement is visualized in real time alongside a B-mode greyscale image. The enhancement characteristics of liver lesions at CEUS are similar to those seen on CT and MR imaging. Since CEUS operates in real time, fast changes during the arterial phase are better captured than on CT or MR.

This presentation discusses the enhancement characteristics of malignant and benign liver lesions. As a general rule, however, lesions which do not washout in the late phase (i.e. remain hyperenhancing or isoenhancing to liver parenchyma) tend to be benign (with the exception of simple cysts, haematomas, ablation cavities and abscesses, which do not enhancement in any phase), whereas lesions which do not retain contrast in the late phase (i.e. demonstrate washout) are usually malignant.

Hepatic metastases have variable appearances on B-mode ultrasound. On CEUS, hypervascular metastases typically demonstrate avid enhancement throughout the lesion in the arterial phase whilst hypovascular metastases show rim enhancement in the arterial phase with both types showing washout in the late phases appearing as defects. CEUS significantly increases the conspicuity of metastases compared to B mode, allowing the detection of isoechoic and lesions down to 3mm.

CEUS and intervention: The use of CEUS may allow better visualisation of a lesion than on B-mode ultrasound and allow a targeted ultrasound-guided biopsy.

CEUS may also be used during interstitial ablation of a focal malignant liver lesion. The operator is able to perform repeated injections of microbubbles in order to establish whether viable tumour remains, and whether immediate further on-table ablative therapy is required.

Benign liver lesions have characteristic enhancement patterns on CEUS. Haemangiomas demonstrate gradual peripheral nodular enhancement with progressive centripetal filling whereas focal nodular hyperplasia typically demonstrate avid arterial centrifugal enhancement in a “spoke wheel” pattern, arising from a central feeding vessel and then become isoenhancing to liver by the late phase.

Focal Fatty Sparing & Focal Fatty Change demonstrate identical enhancement to the surrounding liver parenchyma in all phases of CEUS. CEUS can demonstrate enhancing septa in abscesses. CEUS may indicate suitable drainage sites.

In summary microbubbles have expanded the role of US in the real-time characterisation of focal liver lesions based on specific enhancement patterns to differentiate benign and malignant lesions. Ultrasound contrast agents have significantly improved the sensitivity and specificity of ultrasound to rival that of CT and MR.

References

  1. Claudon M, Dietrich CF, Choi BI, et al: Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver--update 2012: a WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. Ultraschall Med. 2013, 34 (1): 11-29.

    PubMed  CAS  Google Scholar 

  2. Cosgrove DO: Contrast-enhanced ultrasound of liver lesions. Ultrasound Med Biol. 2010, 36: 2146-

    Article  PubMed  Google Scholar 

  3. National Institute for Health and Clinical Excellence: SonoVue (sulphur hexafluoride microbubbles) -contrast agent for contrast-enhanced ultrasound imaging of the liver. August 2012 NICE diagnostics guidance 5. http://www.nice.org.uk/dg5,

  4. Wilson S, Burns P: Microbubble-enhanced US in Body Imaging: What Role?. Radiology. 2010, 257: 24-39. 10.1148/radiol.10091210.

    Article  PubMed  Google Scholar 

  5. Wills M, Harvey C, Kuzmich S, Afaq A, Lim A, Cosgrove D: Characterizing benign liver lesions and trauma with contrast-enhanced ultrasound. Br J Hosp Med. 2014, 75 (2): 91-5. 10.12968/hmed.2014.75.2.91.

    Article  Google Scholar 

  6. Wills M, Harvey C, Kuzmich S, Afaq A, Lim A, Cosgrove D: Characterizing malignant liver lesions with contrast-enhanced ultrasound. Br J Hosp Med. 2014, 75 (3): 151-4. 10.12968/hmed.2014.75.3.151.

    Article  Google Scholar 

  7. Strobel D, Bernatik T, Blank W, et al: Diagnostic accuracy of CEUS in the differential diagnosis of small (≤20 mm) and subcentimetric (≤10 mm) focal liver lesions in comparison with histology. Results of the DEGUM multicenter trial. Ultraschall Med. 2011, 32 (6): 593-7.

    Article  PubMed  CAS  Google Scholar 

  8. Bernatik T, Seitz K, Blank W, et al: Unclear focal liver lesions in contrast-enhanced ultrasonography--lessons to be learned from the DEGUM multicenter study for the characterization of liver tumors. Ultraschall Med. 2010, 31 (6): 577-81. 10.1055/s-0029-1245649.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chris Harvey.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Harvey, C. Ultrasound with microbubbles. Cancer Imaging 15 (Suppl 1), O19 (2015). https://doi.org/10.1186/1470-7330-15-S1-O19

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1470-7330-15-S1-O19

Keywords