Abstract

Background

Vascular features are not commonly used to evaluate thyroid nodules by conventional ultrasound due to the low sensitivity. Superb Microvascular Imaging (SMI) is a new ultrasonic Doppler technology that specializes in depicting microvessels and low-speed flow. The objective of this study was to explore the value of microflow features on SMI in differentiating malignant from benign thyroid nodules.

Methods

One hundred and seventy-seven adult patients with thyroid nodules in our center from October 2021 to June 2022 with available histopathological results were recruited, including 125 malignant nodules and 123 benign nodules. Preoperative ultrasound was performed using greyscale, Color Doppler Flow Imaging (CDFI), monochrome SMI (mSMI) and color SMI (cSMI). Vascular features such as flow richness, microflow distribution and microflow patterns of malignant thyroid nodules were compared with those of benign nodules.

Results

Penetrating vessel ≥ 1 (82.4% in the malignant group vs. 30.9% in the benign group, P < 0.001), the crab claw-like pattern (64.0% vs. 10.6%, P < 0.001) and the root hair-like pattern (8.0% vs. 2.4%, P = 0.049) were common in malignant thyroid nodules, among which the crab claw-like pattern was an independent risk factor for malignant thyroid nodules. The wheel-like pattern (1.6% in the malignant group vs. 33.3% in the benign group, P < 0.001) and the arborescent pattern (0 vs. 19.5%, P < 0.001) were more likely to appear in benign nodules. The diagnostic specificities of the crab claw-like pattern and the root hair-like pattern for malignant thyroid nodules were 0.894, 0.976, and the positive predictive values were 0.860, 0.769. The diagnostic specificities of the wheel-like pattern and the arborescent pattern for benign thyroid nodules were 0.984, 1.000, and the positive predictive values were 0.953, 1.000.

Conclusions

The crab claw-like pattern and the root hair-like pattern were microflow characteristics of malignant thyroid nodules. The wheel-like pattern and the arborescent pattern could help exclude the diagnosis of thyroid cancer.

Background

Recent years have witnessed an increase in the diagnosis of thyroid nodules [1]. The prevalence of thyroid nodules detected by high-resolution ultrasound can reach 68% in adults [2]. However, only 10%-15% are malignant and need clinical intervention [3]. Therefore, it is important to distinguish malignant from benign thyroid nodules. Ultrasound is the preferred examination method for thyroid lesions. The American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) [4] is widely used to evaluate the thyroid nodules according to the ultrasonic composition, echogenicity, margin, shape and echogenic foci. However, the greyscale features of benign and malignant thyroid nodules often overlap [5, 6]. More and more scholars are pursuing new methods and techniques.

The occurrence, development, invasion and metastasis of tumors are highly dependent on angiogenesis [7]. Excessive epithelial cells and perithelial cells promote the construction and extension of neovessels of thyroid cancer [8]. Theoretically, malignant thyroid nodules can be identified by different vascular features. Some researchers believed that the evaluation of the morphology and structure of vessels might be important for the differential diagnosis of thyroid nodules [9]. However, Color Doppler Flow Imaging (CDFI) is of limited use since it cannot display microvessels less than 0.1 mm in diameter or the microflow at a velocity less than 1 mm/s [10] with large observer variance. Spectral Doppler can detect abnormal flow parameters of malignant thyroid nodules, but the sensitivity is low [11]. Contrast enhanced ultrasound (CEUS) can clearly show the microflow of nodules, which benefits the diagnosis [12]. However, CEUS is an invasive examination, and its use is restricted by contrast agent contraindications. In view of these, vascularity, an important ultrasound feature, has not been included in the guidelines for ultrasonic evaluation of thyroid nodules and is not widely used.

As the third generation of ultrasonic Doppler technology after CDFI and Power Doppler Flow Imaging (PDFI), Superb Microvascular Imaging (SMI) may greatly solve the above problems. It can preserve the tiny flow signals and remove the clutter with the new algorithm and developed wall filter. In addition, it is safer and more convenient for free of contrast agents. Our study aimed to explore the vascular features of benign and malignant thyroid nodules, including richness, size, morphology, distribution and patterns of microflow, and to sort out new ultrasound indices for the noninvasive evaluation of thyroid nodules on SMI.

Methods

Study population

This retrospective study was approved by the Institutional Review Board of Peking Union Medical College Hospital (protocol number K3557) and the written informed consent of all patients was obtained. From October 2021 to June 2022, 200 consecutive adult patients with thyroid nodules who planned to undergo greyscale and SMI ultrasound examination as well as thyroid surgery in our center were prospectively recruited. The inclusion criteria were (a) greyscale ultrasound could clearly show the thyroid nodules, (b) solid or predominantly solid nodules, (c) the total thyroidectomy or lobectomy was planned to be performed within one week after the ultrasound examination, and the histopathological results were available after the operation. 23 patients were excluded for the following reasons: [1] the vascularity detection of the nodules near the cervical arteries was influenced by the arterial pulsation (n = 12), (b) acoustic shadow of the coarse calcification at the anterior of the nodules covered the flow signals (n = 9); (c) patients had preoperative treatment like thermal ablation therapy (n = 2). If the patient had more than one thyroid nodule, all the nodules matching the criteria were included. Finally, 177 patients (248 thyroid nodules) were enrolled in this research.

Imaging acquisition

One radiologist with 4 years of experience in ultrasound scanning performed the examinations using Aplio 900 (Canon Medical Systems Corp., Tokyo, Japan) equipped with a 5-18 MHz linear transducer. Patients were instructed to lie supine, tilt the head back to fully expose the examination area and breathe smoothly, avoiding swallowing as much as possible. All nodules were carefully scanned in transverse and longitudinal planes on greyscale first. Then the CDFI and SMI examinations were performed for vascular features with no extra pressure applied to the transducer to avoid vessel collapse. The region of interest included the entire nodule and approximately 3–5 mm of the surrounding parenchyma on CDFI and SMI. The color gain was set to the maximum to exactly suppress the background noise. CDFI scale was set < 6.5 cm/s, frame rate 15f/s, dynamic range 60 dB. SMI scale at 1.0–2.5 cm/s, frame rate 25-60f/s, dynamic range 60 dB. Every nodule was scanned on monochrome SMI (mSMI) and color SMI (cSMI) modes respectively. Since mSMI is more sensitive to microflows [13], it served as the main mode for evaluating the microflow features, with cSMI helping to distinguish microflow from calcification. Smart-3D was also built to show the three-dimensional microflow pattern based on cSMI and instruct the plane selection for the one with the richest flow signals, which was used for microflow features analysis. Spectral Doppler was used to confirm the real vessels when necessary. The largest transverse and longitudinal planes on greyscale of every nodule, cine clips on CDFI and SMI and planes with the richest blood flow were saved.

Imaging analysis

Blinded to the clinical and pathological information of the patients, two radiologists with over 5 years of experience in thyroid ultrasound independently analyzed all the images and videos. One of the two radiologists reviewed again 6 months later still unaware of the above information. The size of nodules was defined as the largest diameter. The greyscale features were assessed according to the ACR TI-RADS [4]. Solid composition, hypoechogenicity or very hypoechogenicity, irregular margin or extrathyroidal extension, taller-than-wide shape and microcalcification were acknowledged as greyscale malignant features. The flow richness of nodules was evaluated based on Adler’s grading [14]. For grade 0, no blood flow was detected; one or two pixels containing flow was considered grade 1; grade 2 was assigned for a main vessel and/or several small vessels (less than 1 mm in diameter); grade 3 included 4 or more vessels. The penetrating vessel referred to the vessel going from the outside to the inside of the nodule [15].

Besides these, microflow features included morphology, size, distribution and pattern. Microflow morphology was classified as dot-like, linear and tortuous. “Dot-like” meant that all microflows were dot-like on SMI. If over half of the microflows in one nodule were linear or tortuous, it was defined as “linear” or “tortuous”, respectively. The microflow size categories were dot-like, tiny and bulky. The “dot-like” was defined in the same way as that in microflow morphology. If over half of the microflows in one nodule were observed only on SMI, it was defined as “tiny”. And “bulky” was given when over half of the microflows in one nodule could be observed on both CDFI and SMI. The distribution of microflows was divided into five types: avascularity, peripheral vascularity, mainly peripheral vascularity, mainly central vascularity and mixed vascularity (the abundance of both central and peripheral vessels in the nodules is similar) [16].

The microflow pattern was defined as the architecture formed by the internal and peripheral microflow of nodules together. We summarized 7 common patterns for thyroid nodules during the study which covered the microflow patterns of the majority of our nodules (Fig. 1). The crab claw-like pattern was an aggregation of multiple penetrating vessels converging from the outside to the inside of the nodule (Fig. 1a-c). The root hair-like pattern was defined as a bulky penetrating vessel with several branches inside of the nodule (Fig. 1d-f). The wheel-like pattern indicated the microflow architecture was dominated by peripheral circumferential vessels with several branches going into the nodule (Fig. 1g-i). The arborescent pattern referred to a large branch from the circumferential vessel extending into the nodule with several small branches (Fig. 1j-l). The scattered-dot pattern denoted only one or more dot-like vessels inside or at the margin of the nodule (Fig. 1m-o). The circumferential pattern represented one or more vessels surrounding the nodule (Fig. 1p-r). Some nodules presented only one penetrating vessel, defined as the single penetrating vessel pattern (Fig. 1s-u).

Fig. 1
figure 1

Microflow patterns of thyroid nodules in diagrams, cSMI and mSMI. a-c shows the crab claw-like pattern. d-f shows the root hair-like pattern. g-i shows the wheel-like pattern. j-l shows the arborescent pattern. m–o shows the scattered-dot pattern. p-r shows the circumferential pattern. s-u shows the single penetrating vessel pattern

Statistical analysis

Data were analyzed using SPSS software version 21.0 (SPSS Inc., Chicago, IL). The age of patients, the size and penetrating vessel number of nodules were continuous variables that did not form a normal distribution, and were expressed as median (interquartile range). Mann–Whitney test was used for the comparation of these indices between the benign and malignant groups. Differences in penetrating vessel numbers on CDFI and SMI within groups were analyzed by Wilcoxon test. Receiver operator characteristic (ROC) curve was used to get the best cutoff value of penetrating vessel number to diagnose malignant thyroid nodules. Other microflow features were categorical variables and chi-square test was used for the comparation between the benign and malignant groups. All statistical tests were bilateral, and a P-value < 0.05 was considered statistically significant. The weighted Kappa was used for intra- and interobserver agreement of Adler’s grading, and the Cohen’s Kappa was used for other microflow features. The Kappa-value mirrors the intra- and interobserver agreement, with values 0.01–0.20 slight agreement, 0.21–0.40 fair agreement, 0.41–0.60 moderate agreement, 0.61–0.80 substantial agreement and 0.81–0.99 almost perfect agreement [17]. P-value < 0.05 and Kappa-value > 0.60 were used to sort the microflow features. Histopathological results were used as the gold standard to analyze the diagnostic validity of the selected vascular features. Multivariate logistic regression was used for the independent risk factor of thyroid cancer.

Result

Demographic and pathology data

In all, 248 thyroid nodules of 177 patients were included in our study, among which 125 were malignant and 123 were benign. The male-to-female ratio of patients was 1:2.85 and the median age was 40 years (interquartile range: 33–52 years). The median size of nodules was 0.8 cm (interquartile range: 0.6–1.3 cm). The difference between the benign and malignant groups was not statistically significant (P = 0.125). All the malignant nodules were papillary thyroid carcinoma. In the benign group, 71 nodules were nodular goiter, 37 were thyroid adenoma, 12 were focal lymphocytic thyroiditis, 2 were subacute granulomatous thyroiditis and 1 was follicular epithelial hyperplasia.

Vascular features analysis

The Adler’s grading distribution and penetrating vessel number of thyroid nodules on CDFI and SMI were shown in Table 1. Seven nodules which displayed no flow signal on CDFI showed dot- or rod-like flow signals on SMI. There were statistically significant differences between CDFI and SMI in evaluating Adler’s grading and the number of penetrating vessels of benign and malignant thyroid nodules (P < 0.001). ROC curves suggested that the best cutoff values of penetrating vessel number in diagnosing malignant thyroid nodules on CDFI and SMI were penetrating vessel ≥ 1.

Table 1 The flow richness of thyroid nodules between the malignant and benign groups

The microflow features of benign and malignant thyroid nodules on SMI were summarized in Table 2. For morphology, 72.8% malignant nodules had predominantly tortuous microflows and 61.0% benign nodules had predominantly linear microflows (P < 0.001).

Table 2 Microflow features of thyroid nodules between the malignant and benign groups

The diagnostic performance of microflow patterns on SMI

Table 2 showed that, in aspect of microflow patterns, the crab claw-like pattern was common in malignant nodules (64.0% in the malignant group vs. 10.6% in the benign group, P < 0.001) (Fig. 2). The root hair-like pattern (8.0% vs. 2.4%, P = 0.049) and the single penetrating vessel pattern (8.8% vs. 2.4%, P = 0.030) were more likely to appear in malignant nodules. Among these, the crab claw-like pattern and the root hair-like pattern were sorted out for substantial intra- and interobserver agreement (Kappa > 0.60, Fig. 3). The diagnostic performances of the crab claw-like pattern and the root hair-like pattern for malignant thyroid nodules were shown in Table 3 with greyscale malignant features. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the crab claw-like pattern were 0.640, 0.894, 0.860, 0.710, 0.766. The diagnostic sensitivity, specificity, PPV, NPV and accuracy of the root hair-like pattern were 0.080, 0.976, 0.769, 0.511, 0.524.

Fig. 2
figure 2

Ultrasound images of a papillary thyroid carcinoma of classic variant in a 42 female patient. a The lesion presented as a hypoechoic solid nodule with irregular margin on greyscale. b CDFI showed scattered dot- and rod-like flow signals at the margin of the nodule. c CSMI showed a crab claw-like pattern. d. MSMI showed a crab claw-like pattern

Fig. 3
figure 3

Intra- and interobserver agreement in the assessment of thyroid nodules using SMI

Table 3 Diagnostic performances of US features for malignant thyroid nodules

The wheel-like pattern (1.6% in the malignant group vs. 33.3% in the benign group, P < 0.001) (Fig. 4), the arborescent pattern (0 vs. 19.5%, P < 0.001) and the circumferential pattern (2.4% vs. 15.4%, P < 0.001) often emerged in benign nodules. Among these, the wheel-like pattern and the arborescent pattern were sorted out for substantial intra- and interobserver agreement (Kappa > 0.60, Fig. 3). The diagnostic sensitivity, specificity, PPV, NPV and accuracy of the wheel-like pattern for benign thyroid nodules were 0.333, 0.984, 0.953, 0.600, 0.661. The diagnostic sensitivity, specificity, PPV, NPV and accuracy of the arborescent pattern for benign thyroid nodules were 0.195, 1.000, 1.000, 0.558, 0.601.

Fig. 4
figure 4

Ultrasound images of a nodular goiter in a 49 female patient. a The lesion presented as a mixed solid and cystic nodule on greyscale. b CDFI showed several dot- and rod-like flow signals inside and around the nodule. c CSMI showed a wheel-like pattern. d MSMI showed a wheel-like pattern

After screening by P-value < 0.05 and Kappa-value > 0.6, penetrating vessel ≥ 1, the crab claw-like pattern and the root hair-like pattern were selected for multivariate logistic regression together with greyscale malignant features. The results (Fig. 5) showed that the crab claw-like pattern was an independent risk factor of malignant thyroid nodules besides solid composition, irregular margin or extrathyroidal extension, taller-than-wide shape and microcalcification. The odds ratio of the crab claw-like pattern was 5.720, ranking third behind the microcalcification and solid composition.

Fig. 5
figure 5

Forest plot of odds ratios of the selected ultrasound features in multivariate logistic regression analysis

Discussion

This study analyzed the microvascular features, including richness, size, morphology, distribution and pattern, of 248 thyroid nodules in 177 patients on SMI. After selecting features based on substantial intra- and interobserver agreement, we found that penetrating vessel ≥ 1, the crab claw-like pattern and the root hair-like pattern were common in malignant thyroid nodules and the crab claw-like pattern was an independent risk factor for thyroid cancer. The wheel-like pattern and the arborescent pattern were more likely to appear in benign thyroid nodules.

Our results showed that the crab claw-like pattern and the root hair-like pattern owned great diagnostic specificity and PPV for malignant thyroid nodules, especially for the crab claw-like pattern. As an independent risk factor for thyroid cancer, the crab claw-like pattern had an odds ratio only lower to those of microcalcification and solid composition in multivariate logistic regression, suggesting a clinical value comparable to the widely acknowledged greyscale malignant features. Wu J et al. [6] also found that malignant thyroid nodules were more likely to exhibit numerous tortuous flows with chaotic directions and irregular small branches on SMI angiography. The crab claw-like pattern and the root hair-like pattern were based on the penetrating vessel ≥ 1. The former was an integration of multiple penetrating vessels, which conformed to the tumor angiogenesis. When the size is larger than 10 mm3 or there are more than 107 cells, the tumor will recruit the surrounding vessels and neovessels will bud through the epithelial cells of the original vessels and grow into the tumor [7, 18]. Yongfeng Z et al. [19] found the microvessel density was higher in the periphery of thyroid cancer pathologically, which was consistent with their result that malignant nodules were dominated by peripheral microvessels. The root hair-like pattern might indicate further growth of the penetrating vessel for it giving off branches inside the nodules.

The wheel-like pattern and the arborescent pattern on SMI aided in the exclusion of thyroid cancer. In our study, 33.3% benign nodules presented wheel-like patterns and 19.5% presented arborescent patterns. Both had great specificity and PPV for diagnosing benign thyroid nodules. The wheel-like pattern and the arborescent pattern were built on circumferential vessels. The former displayed multiple branches, and the latter emphasized the growth of one branch. These patterns were due to the compression effect of benign nodules on the surrounding vessels in the nearby parenchyma, and branches were birthed from these surrounding vessels [20]. There were scarce reports about the microflow patterns of benign thyroid nodules on SMI. However, ring enhancement of thyroid adenoma on CEUS, with rapid and intense vascularization in the periphery and slow vascularization in the center [12], was similar to the wheel-like pattern and the arborescent pattern on SMI.

We found that SMI could display vascular richness and penetrating vessels better than CDFI. Machado et al. [21] found SMI showed the microvessels of thyroid nodules in a more comprehensive and detailed way since SMI could detect flow at a lower speed compared with CDFI and PDFI. Yongfeng Z et al. [19] semi-quantified the vascular richness of thyroid nodules on SMI and found that it was consistent with pathological microvessel density. Notably, SMI was superior in visualizing penetrating vessels, which was consistent with the results of Diao X et al. [22]. Kong J et al. [23] discovered that some peripheral flows on PDFI were exactly tiny penetrating vessels on SMI in several malignant thyroid nodules. Penetrating vessels were acknowledged to be closely related to carcinoma. They were the manifestation of tumor angiogenesis [15] and was important to differentiate benign and malignant thyroid nodules. Zhang L et al. [24] found that penetrating vessel detected by SMI was an independent risk factor for malignant thyroid nodules of TI-RADS 4. Our results showed that penetrating vessel ≥ 1 on SMI had great sensitivity, but it was not an independent risk factor for malignant thyroid nodules.

We also explored the microflow morphology, size and distribution features of thyroid nodules on SMI but found limited values. Our results showed that 72.8% malignant nodules had tortuous microflows and 61.0% benign nodules had linear microflows (P < 0.001), similar to the results of some scholars [6, 13]. However, the interobserver agreement was too low for these features to be used clinically. This can be attributed to the ambiguous criteria for microflow morphology and the numerous tiny vessels observed on SMI. Some scholars found differences in microflow distribution on SMI between benign and malignant thyroid nodules, but the conclusions were variable or even contradictory. In the study of Zhang L et al. [24], 65% malignant nodules had predominantly central microvessels. Kong J et al. [23] found that intranodular vascularity on SMI including penetrating vessels was an independent risk factor for malignant thyroid nodules. Nevertheless, the results of Chambara et al. [25] demonstrated no disparity between predominantly peripheral vascularity and predominantly central vascularity in malignant nodules. Interestingly, Yongfeng Z et al. [19] believed predominantly peripheral vascularity was the ultrasound feature for malignant nodules. Our results showed the difference in microflow distribution between the benign and malignant groups was not statistically significant. We attributed this discrepancy to the different definitions for microflow distribution and the difficulty in assessing the distribution for nodules with rich microflows.

Our study had some limitations. First, there was selection bias among patients. We included neither nodules with coarse calcification at the anterior or situated near the large arteries nor the patients who underwent fine needle aspiration without surgery or who only had follow-up data, which inevitably resulted in the loss of some benign nodules. Plus, the pathologic type in our study was relatively homogeneous since all the malignant thyroid nodules were papillary thyroid carcinomas. Moreover, the sample size of this study was not big enough and the research was based on a single center. Multi-center research is needed to explore the value of SMI in diagnosing thyroid nodules.

Conclusion

Microflow patterns on SMI aided in the differential diagnosis of thyroid nodules. The crab claw-like pattern and the root hair-like pattern were malignant ultrasound features for thyroid nodules. The wheel-like pattern and the arborescent pattern could help exclude the thyroid cancer.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

SMI:

Superb Microvascular Imaging

mSMI:

Monochrome Superb Microvascular Imaging

cSMI:

Color Superb Microvascular Imaging

CDFI:

Color Doppler Flow Imaging

ACR TI-RADS:

American College of Radiology Thyroid Imaging Reporting and Data System

CEUS:

Contrast Enhanced Ultrasound

PDFI:

Power Doppler Flow Imaging

ROC:

Receiver Operator Characteristic

PPV:

Positive Predictive Value

NPV:

Negative Predictive Value

References

  1. Durante C, Grani G, Lamartina L, Filetti S, Mandel SJ, Cooper DS. The diagnosis and management of thyroid nodules: a review. JAMA. 2018;319(9):914–24.

    Article  PubMed  Google Scholar 

  2. Haugen BRAE, Bible KC, Doherty GM, Mandel SJ, Nikiforov YE, Pacini F, Randolph GW, Sawka AM, Schlumberger M, Schuff KG, Sherman SI, Sosa JA, Steward DL, Tuttle RM, Wartofsky L. 2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association guidelines task force on thyroid nodules and differentiated thyroid cancer. Thyroid. 2016;26:1–133.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Alexander EK, Cibas ES. Diagnosis of thyroid nodules. Lancet Diabetes Endocrinol. 2022;10(7):533–9.

    Article  PubMed  Google Scholar 

  4. Tessler FNMW, Grant EG, Hoang JK, Berland LL, Teefey SA, Cronan JJ, Beland MD, Desser TS, Frates MC, Hammers LW, Hamper UM, Langer JE, Reading CC, Scoutt LM, Stavros AT. ACR thyroid imaging, reporting and data system (TI-RADS): white paper of the ACR TI-RADS Committee. J Am Coll Radiol. 2017;14:587–95.

    Article  PubMed  Google Scholar 

  5. Pei S, Cong S, Zhang B, Liang C, Zhang L, Liu J, et al. Diagnostic value of multimodal ultrasound imaging in differentiating benign and malignant TI-RADS category 4 nodules. Int J Clin Oncol. 2019;24(6):632–9.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Wu J, Zhan T, Sun H, Wang F. The application value of SMI technology and contrast-enhanced ultrasound in the differential diagnosis of benign and malignant thyroid nodules. Contrast Media Mol Imaging. 2022;2022:6157026.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Folkman J. Tumor angiogenesis: therapeutic implications. N Engl J Med. 1971;285(21):1182–6.

    Article  CAS  PubMed  Google Scholar 

  8. Tasoulas J, Tsourouflis G, Theocharis S. Neovascularization: an attractive but tricky target in thyroid cancer. Expert Opin Ther Targets. 2018;22(9):799–810.

    Article  PubMed  Google Scholar 

  9. Sancak S, Hardt A, Gartner R, Eszlinger M, Aslan A, Eren FT, et al. Comparison of Color Flow Doppler Sonography (CFDS) and immunohistologic detection of microvessels for the assessment of the malignancy of thyroid nodules. Horm Metab Res. 2010;42(9):670–6.

    Article  CAS  PubMed  Google Scholar 

  10. Schroeder RJ, Bostanjoglo M, Rademaker J, Maeurer J, Felix R. Role of power doppler techniques and ultrasound contrast enhancement in the differential diagnosis of focal breast lesions. Eur Radiol. 2003;13(1):68–79.

    Article  PubMed  Google Scholar 

  11. De Nicola H, Szejnfeld J, Logullo AF, Wolosker AM, Souza LR, Chiferi V Jr. Flow pattern and vascular resistive index as predictors of malignancy risk in thyroid follicular neoplasms. J Ultrasound Med. 2005;24(7):897–904.

    Article  PubMed  Google Scholar 

  12. Radzina M, Ratniece M, Putrins DS, Saule L, Cantisani V. Performance of Contrast-Enhanced Ultrasound in Thyroid Nodules: Review of Current State and Future Perspectives. Cancers (Basel). 2021;13(21):5469.

  13. Xiao XY, Chen X, Guan XF, Wu H, Qin W, Luo BM. Superb microvascular imaging in diagnosis of breast lesions: a comparative study with contrast-enhanced ultrasonographic microvascular imaging. Br J Radiol. 2016;89(1066):20160546.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Adler DD, Carson PL, Rubin JM, Quinn-Reid D. Doppler ultrasound color flow imaging in the study of breast cancer: preliminary findings. Ultrasound Med Biol. 1990;16(6):553–9.

    Article  CAS  PubMed  Google Scholar 

  15. Ibrahim R, Rahmat K, Fadzli F, Rozalli FI, Westerhout CJ, Alli K, et al. Evaluation of solid breast lesions with power Doppler: value of penetrating vessels as a predictor of malignancy. Singapore Med J. 2016;57(11):634–40.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Zhou J, Yin L, Wei X, Zhang S, Song Y, Luo B, et al. 2020 Chinese guidelines for ultrasound malignancy risk stratification of thyroid nodules: the C-TIRADS. Endocrine. 2020;70(2):256–79.

    Article  CAS  PubMed  Google Scholar 

  17. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159–74.

    Article  CAS  PubMed  Google Scholar 

  18. Gu J, Ternifi R, Sabeti S, Larson NB, Carter JM, Fazzio RT, et al. Volumetric imaging and morphometric analysis of breast tumor angiogenesis using a new contrast-free ultrasound technique: a feasibility study. Breast Cancer Res. 2022;24(1):85.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Yongfeng Z, Ping Z, Hong P, Wengang L, Yan Z. Superb microvascular imaging compared with contrast-enhanced ultrasound to assess microvessels in thyroid nodules. J Med Ultrason (2001). 2020;47(2):287–97.

    Article  PubMed  Google Scholar 

  20. Jiang J, Shang X, Wang H, Xu YB, Gao Y, Zhou Q. Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification. Kaohsiung J Med Sci. 2015;31(3):138–44.

    Article  PubMed  Google Scholar 

  21. Machado P, Segal S, Lyshchik A, Forsberg F. A novel microvascular flow technique: initial results in thyroids. Ultrasound Q. 2016;32(1):67–74.

    Article  PubMed  Google Scholar 

  22. Diao X, Zhan J, Chen L, Chen Y, Cao H. Role of superb microvascular imaging in differentiating between malignant and benign solid breast masses. Clin Breast Cancer. 2020;20(6):e786–93.

    Article  PubMed  Google Scholar 

  23. Kong J, Li JC, Wang HY, Wang YH, Zhao RN, Zhang Y, et al. Role of superb micro-vascular imaging in the preoperative evaluation of thyroid nodules: comparison with power doppler flow imaging. J Ultrasound Med. 2017;36(7):1329–37.

    Article  PubMed  Google Scholar 

  24. Zhang L, Gu J, Zhao Y, Zhu M, Wei J, Zhang B. The role of multimodal ultrasonic flow imaging in thyroid imaging reporting and data system (TI-RADS) 4 nodules. Gland Surg. 2020;9(5):1469–77.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Chambara N, Liu SYW, Lo X, Ying M. Diagnostic value of AngioPLUS microvascular imaging in thyroid nodule diagnosis using quantitative and qualitative vascularity grading. Biomedicines. 2022;10(7):1554.

Download references

Acknowledgements

The authors would like to thank AJE (https://www.aje.cn/) for English language editing.

Funding

This work was supported by grants from the National Natural Science Foundation of China (grant number 61971448, 82001853), the National High Level Hospital Clinical Research Funding (grant number 2022-PUMCH-B-064), the Fundamental Research Funds for the Central Universities (grant number 3332023011) and the Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences (grant number 2020-RW330-003).

Author information

Authors and Affiliations

Authors

Contributions

WL performed the statistical analysis and wrote the manuscript. LG participated in image analysis and revised the manuscript. YD performed the ultrasound examination. YW also participated in image analysis. XY provided advice on the interpretation of the results. HW and JL conceived of and designed the study. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Hongyan Wang or Jianchu Li.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Institutional Review Board of Peking Union Medical College Hospital (protocol number K3557), and the written informed consent was obtained from all patients in this study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, W., Gao, L., Du, Y. et al. Ultrasound microflow patterns help in distinguishing malignant from benign thyroid nodules. Cancer Imaging 24, 18 (2024). https://doi.org/10.1186/s40644-024-00663-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40644-024-00663-1

Keywords