Skip to main content

Table 4 Pre-operative CT T staging and post-operative pathologic T staging in esophageal cancer patients (n = 74)

From: A prospective analysis of the diagnostic accuracy of 3 T MRI, CT and endoscopic ultrasound for preoperative T staging of potentially resectable esophageal cancer

Pre-operative CT T staging

Pre-operative pathologic T staging

Sensitivity

Specificity

Accuracy

T1/T2 (n = 45)

T3/T4 (n = 29)

Reader 3

T1/T2

38

7

84% (38/45) (CI: 70.54 93.51%)

79% (23/29) (CI: 60.28–92.01%)

82% (61/74) (CI: 71.83–90.30%)

T3/T4

6

23

Reader 4

T1/T2

38

7

84% (38/45) (CI: 70.54–93.51%)

72% (21/29) (CI: 52.76–87.27%)

80% (59/74) (CI: 68.78–88.19%)

T3/T4

8

21