Skip to main content

Table 5 Subjective image quality scores between different reconstruction groups of the low-activity cohort

From: A personal acquisition time regimen of 68Ga-DOTATATE total-body PET/CT in patients with neuroendocrine tumor (NET): a feasibility study

Groups

Mean scores

Inter-reader agreement

Intra-reader agreement

Reviewer 1

Reviewer 2

  

kappa

95% CI

kappa

95% CI

kappa

95% CI

R1

1.51 ± 0.50

0.93

0.92 ~ 0.94

0.94

0.90 ~ 0.97

0.95

0.91 ~ 0.97

R2

2.44 ± 0.54

0.90

0.88 ~ 0.92

0.98

0.97 ~ 0.99

0.95

0.92 ~ 0.97

R3

3.44 ± 0.53

0.97

0.96 ~ 0.98

0.95

0.91 ~ 0.97

0.97

0.95 ~ 0.98

R4

4.44 ± 0.57

0.97

0.96 ~ 0.98

0.97

0.95 ~ 0.98

1.00

-

R5

5.00 ± 0.00

1.00

-

1.00

-

1.00

-

R8

5.00 ± 0.00

1.00

-

1.00

-

1.00

-

R10

5.00 ± 0.00

1.00

-

1.00

-

1.00

-

  1. Mean scores were the mean of two reviewer’s score
  2. Cohen’s kappa analysis of overall image quality was used to evaluate the inter/intra-reader agreement
  3. Data are presented as the mean ± standard deviation