Skip to main content

Table 3 Results of Quantitative Assessment of primary rectal cancer

From: Integrated slice-specific dynamic shimming diffusion weighted imaging (DWI) for rectal Cancer detection and characterization

 

t test

ROC analysis

 

Images

 

Average

t

P

Area under curve

P

SIlesion

SIrectum

b800

SIlesion

221.68 ± 43.51

16.868

< 0.001*

–

SIrectum

103.99 ± 42.68

b1600

SIlesion

143.28 ± 32.9

20.468

< 0.001*

SIrectum

48.94 ± 23.69

b1000

SIlesion

125.86 ± 32.14

17.441

< 0.001*

SIrectum

65.51 ± 15.57

ADClesion

ADCrectum

iShim-DWI

ADClesion

0.763 ± 0.13

−11.103

< 0.001*

ADCrectum

1.294 ± 0.36

SS-EPI-DWI

ADClesion

0.768 ± 0.13

−17.303

< 0.001*

ADCrectum

1.243 ± 0.22

Group

Comparison

In iShim-DWI

ADClesion

(×10−3 mm2/s)

Group 1

0.912 ± 0.21

2.837

0.017*

0.742

0.012*

Group 2

0.732 ± 0.084

SIlesion

of b800

Group 1

191.91 ± 68.08

−1.697

0.118

0.692

0.046*

Group 2

227.64 ± 34.71

SIlesion

of b1600

Group 1

113.95 ± 47.67

−2.379

0.036*

0.756

0.008*

Group 2

149.15 ± 25.92

Group

Comparison

In SS-EPI-DWI

ADClesion

((×10−3 mm2/s)

Group 1

0.815 ± 0.13

1.029

0.308

0.619

0.382

Group 2

0.764 ± 0.1

SIlesion

of b = 1000

Group 1

125.1 ± 29.69

0.663

0.51

0.55

0.714

Group 2

134.6 ± 40.71

  1. P with * suggested statistical significance