Skip to main content

Table 5 Concordance rates of MRI and CAD in 50 ductal carcinoma in situ

From: Preoperative tumor size measurement in breast cancer patients: which threshold is appropriate on computer-aided detection for breast MRI?

 

Manual measurement on MRI a

CAD b with 30% threshold

CAD with 50% threshold

CAD with 100% threshold

Underestimation

16 (32.0) *

15 (30.0)

20 (40.0)

38 (76.0)

Concordance

18 (36.0)

15 (30.0)

17 (34.0)

9 (18.0)

Overestimation

16 (32.0)

20 (40.0)

13 (26.0)

3 (6.0)

Total number

50 (100.0)

50 (100.0)

50 (100.0)

50 (100.0)

p value†

 

0.699

0.744

<  0.001

  1. * Data are numbers of cancers with percentages in parentheses
  2. † The chi-square test was used to compare the outcomes of CAD with that those of MRI as a reference standard
  3. aMRI magnetic resonance imaging, bCAD computer-aided detection