Skip to main content

Table 2 ROC curve analyses representing differentiation of Breast vs. Other, NSCLC vs. Other, Breast vs. NSCLC and pooled Breast & NSCLC groups vs. Other

From: Probabilistic independent component analysis of dynamic susceptibility contrast perfusion MRI in metastatic brain tumors

Parameter

AUC

Cut-off value

Specificity

Sensitivity

Breast vs. Other

 Tumor Volume [μl]

0.62

866

45.3

81.5

 ADC [μm2/ms]

0.533

1.423

25.3

91.2

 rCBV [a.u.]

0.547

2.923

73.5

43.1

 Arterial [%]

0.692

21.809

62.8

75

 Overlap [%]

0.56

54.138

65.2

61.6

Venous [%]

0.698

68.688

90

44.1

NSCLC vs. Other

 Tumor Volume [μl]

0.627

266

68.7

65.3

 ADC [μm2/ms]

0.513

0.972

39.2

72.9

 rCBV [a.u.]

0.51

0.991

87.8

23.1

Arterial [%]

0.658

29.26

72.9

55.4

 Overlap [%]

0.562

18.506

80.3

38.8

 Venous [%]

0.518

10.514

32.6

80

Breast vs. NSCLC

 Tumor Volume [μl]

0.471

1069

25.2

83.3

 ADC [μm2/ms]

0.562

0.991

66.1

47.2

 rCBV [a.u.]

0.554

1.174

28.1

86.2

 Arterial [%]

0.516

9.645

25.7

87.5

 Overlap [%]

0.616

56.675

73.2

48.3

Venous [%]

0.687

46.666

78.4

58.8

Breast & NSCLC vs. Other

 Tumor Volume [μl]

0.625

556

54

68.8

 ADC [μm2/ms]

0.5

1.417

26.1

84.8

 rCBV [a.u.]

0.508

2.886

73.5

47.4

Arterial [%]

0.666

20.202

62.8

76.3

 Overlap [%]

0.523

18.51

80.3

44.6

 Venous [%]

0.583

72.72

92.9

33.4

  1. Tumor volume, ADC, rCBV, ICA-derived arterial, overlap, and venous components were analyzed. For each parameter, area under curve (AUC) representing the accuracy of the measurement, cut-off value, specificity and sensitivity (expressed in %) are reported
  2. BOLD rows in the table represent total characteristics for the entire patient cohort examined in the current study