Skip to main content

Table 1 MRI acquisition details of the T2-TSE, DTI and IVIM protocols

From: Mono, bi- and tri-exponential diffusion MRI modelling for renal solid masses and comparison with histopathological findings

Sequence

T2-TSE

DTI

IVIM

Respiratory correction

Breath hold

Trigger

Trigger

Scan time per breath hold/ respiration

00:15.6

0:02.8

0:03.0

Acquisition plane

Coronal

Coronal

Coronal

Field of view

450 × 450

336 × 204

336 × 204

TSE factor

20

–

–

TR/TE (ms)

1200/80

2799/47

3007/56

Startup echoes

0

–

–

b-value (s/mm2)

–

0, 100, 300

0, 10, 25, 40, 75, 100, 200, 300, 500, 700

Flip angle (deg)

90

–

–

Gradient directions

–

15

6

EPI factor (ETL)

–

61

61

SENSE factor

2

1.5

1.5

Acquisition matrix

412 × 281

112 × 67

112 × 67

Acquisition voxel size (mm3)

1.09 × 1.60 × 3.0

3.0 × 3.0 × 3.0

3.0 × 3.0 × 3.0

Half Fourier scan factor

0.599

0.655

0.655

Slice thickness/gap (mm)

3.0 /−

3.0/−

3.0/−

Number of slices

25

30

30

Number of averages

1

1 (b = 0, 6)

1 (b = 0, 4)

Type of fat suppression

No

SPIR

SPIR

Total acquisition time (min, without trigger)

00:33.6

01:51.0

02:57.4