Table 1 Rectal high-resolution MRI protocols for 2D and 3D sequences

From: Fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI for predicting small node metastases in patients with rectal cancer

Sequences

TR/TE (msec)

Slice thickness/Gap (mm)

No. of slices

Frequency direction

Flip angle (°)

Matrix

FOV (cm)

Voxel size (mm)

Acquisition time

2D-TSE-T2WI

 Sagittal

3000/87

3/0

19

H to F

150

320 × 256

18

0.7 × 0.6 × 3.0

2 min 30 s

 Coronal

4000/77

3/0

25

F to H

137

384 × 308

22

0.7 × 0.6 × 3.0

2 min 52 s

 Oblique axial

3000/84

3/0

24

R to L

150

320 × 320

18

0.6 × 0.6 × 3.0

3 min 18 s

3D-GRE-T1WI

 Coronal

10/4.9

1/0

144

R to L

10

384 × 384

38

1.0 × 1.0 × 1.0

3 min 10 s

  1. Notes: TR repetition time, TE echo time, FOV field of view, H head, F feet, R right, L left