Skip to main content

Table 3 Cross-tabulation of strain score, strain ratio and BI-RADS score against histological diagnosis. BI-RADS 1 and 2 were considered negative while 3–5 were designated positive status

From: Comparison of qualitative and semiquantitative strain elastography in breast lesions for diagnostic accuracy

 

Histology positive

Histology negative

Strain score

Positive

24

3

Negative

4

81

Strain ratio

Positive

26

3

Negative

2

81

BI-RADS classification

Positive

28

11

Negative

0

73